Selection guidePublished:

Volumetric Doser vs Gravimetric Blender for Masterbatch and Regrind

Compare volume-calibrated dosing with weight-based blending by recipe complexity, material variation, component rate, refill, records, and cleaning.

Volumetric Doser vs Gravimetric Blender for Masterbatch and Regrind guide cover

Selection at a glance

Compare the method before selecting a model.

Volumetric doserGravimetric blender
Meters ingredients by calibrated volumeMeasures ingredient batches by weight
Review calibration when material bulk density changesReview batch size, recipe and weighing requirements

Confirm materials, dosing range, required accuracy and throughput.

A volumetric doser runs a screw for a set time and trusts that the same screw movement delivers the same mass. A gravimetric blender weighs what it feeds and corrects against the recipe. That difference decides most of the choice, and it shows up hardest on regrind, because regrind is the one stream whose bulk density will not hold still. If your color stream is a single free-flowing masterbatch at 2 % into stable virgin pellets, a calibrated volumetric doser does the job for a fraction of the cost. If regrind is in the recipe, or you run three or more components, or anyone will ask you to prove the batch weight after the fact, weight-based blending earns its price.

The rest of this page is about where the line actually falls, with numbers.

What each one measures, and what it does not

A screw doser's controller relates screw rotation and run time to an expected volume, and you calibrate that volume against the actual material to get mass per unit time. The device never weighs a dose. Change the bulk density and the same screw movement delivers a different mass.

Gravimetric blending closes that loop. Components enter a weigh chamber or pass a loss-in-weight scale, the controller compares actual weight to the recipe target, and it manages the batching sequence from there. Weight measurement does not fix bad material flow, vibration, refill disturbance, or a batch size too small for the scale's resolution. It only removes the guesswork about how much went in.

One distinction worth keeping straight at quotation time: a gravimetric blender is not a gravimetric feeder. A blender prepares a batch of several ingredients. Continuous loss-in-weight feeding into an extruder throat is a different control problem, and the two get quoted as if they were interchangeable.

The percentage is meaningless until you say by weight

"Two percent color" is not a recipe. Two percent of what, measured how, against which base? A volumetric doser set to 2 % by volume and a gravimetric blender set to 2 % by weight are running different recipes, and on a masterbatch with a bulk density well below the virgin resin the gap between them is not small.

Spell the recipe out component by component: virgin, regrind, masterbatch, filler, each additive as its own stream with its own target and tolerance. Do not fold three minor additives under "additive" if they flow differently or run at different rates. Keep the dosing unit out of the job of deciding how much regrind a product will accept — that is a quality decision, not a feeder setting.

Where volumetric holds its ground

Single-component masterbatch dosing into a stable virgin stream is the classic case, and it is a good one. The masterbatch arrives in the same grade, same pellet size, same bulk density, lot after lot. You calibrate once, check on a schedule, and the screw repeats. A single-component masterbatch doser is a small, cheap, mechanically simple device, and there is no reason to put a load cell on it.

The moment bulk condition drifts, the calibration is stale. A different masterbatch lot with a finer grind, a switch from 25 kg bags to an octabin, a color change to a lower-density grade: each one shifts grams per screw revolution, and the machine will not tell you. It keeps running the same screw time and delivering a different percentage. Recalibrate after material or lot changes, and treat the calibration record as part of the recipe.

Multi-component volumetric arrangements exist, and KYSHIN's dual-component volumetric doser meters two streams by controlled volume for a defined ratio range. Two streams, though, is not the same problem as five.

A worked example: why regrind breaks volume calibration

Take a press running a 300 g shot on a 25-second cycle. That is 43.2 kg/h of total throughput, and the recipe calls for 20 % regrind, so 8.64 kg/h of regrind has to be fed.

Suppose a dual-component volumetric unit or a side-feeder was calibrated on regrind at 0.55 kg/L, a clean, uniform granulate from a well-set granulator, while the virgin resin enters by gravity through the main throat. Now the granulator screen changes, or the scrap mix shifts toward thin-wall parts, and the regrind bulk density drops to 0.42 kg/L. Same screw speed, same run time. The regrind screw is now delivering 0.42 ÷ 0.55, or 76.4 % of the mass it was calibrated for — about 6.60 kg/h instead of 8.64 kg/h. Because the flood-fed virgin resin makes up the remaining 36.60 kg/h demanded by the press screw, the actual regrind fraction in the part falls from 20 % to 6.60 ÷ 43.2 = 15.3 % (or if both streams are metered volumetrically at fixed speeds, 6.60 ÷ (34.56 + 6.60) = 16.0 %).

Nobody sees an alarm. The part may look fine. What changed is the melt viscosity, the shrink, and the cost per part, and if the regrind was carrying a different pigment load than the virgin, the color shifts too. A gravimetric blender sees the weight and corrects within the batch. A volumetric doser sees nothing.

This is the honest limitation of volumetric dosing: it cannot detect the thing that most often goes wrong. It is not inaccurate on stable material. It is blind on unstable material, and regrind is unstable by nature.

Sizing the minor component is the harder half

Total throughput rarely decides the machine. The smallest component does.

A blender rated for 200 kg/h total may still be a poor fit if your anti-block additive runs at 0.3 %, which on 43.2 kg/h of throughput is 130 g/h. Whether a given weigh chamber can resolve and control 130 g/h depends on batch size, scale resolution, and the feeder gate, and that is a question for the supplier against your actual rate, not something the nameplate answers. The same trap catches volumetric dosers: a screw sized for a low color rate may not deliver enough when the line runs a heavier masterbatch loading on a different product.

Derive the demand from real process data. Shot weight, cycle time, cavity count, uptime. For extrusion, the validated line consumption across the operating range, including startup and purge. Motor power and clamp force tell you nothing about the mass entering the feeder.

Mounting, refill, cleaning, and the records question

Where the unit sits changes the process. A doser feeding directly above a machine throat has almost no downstream mixing volume; components combined right before the screw rely on the screw itself to blend them. A blender on a stand in the material area can mix properly, but if the blend is then conveyed, differential particle size and density can separate it again on the way. The whole path from storage to throat belongs in the layout.

Refill is where stable dosing quietly falls apart. A component hopper running near empty changes head pressure and flow; a refill pulse adds vibration that disturbs a weigh cycle. Vacuum loaders need their discharge and controls coordinated so every component stays available without crossing source identities. If the resin is hygroscopic, decide whether dosing happens before or after drying, because a hopper dryer and loader combination at the throat puts the drying step downstream of the blender and changes what the blender sees.

Color and material changes also turn cleaning into a selection factor. More components mean more hoppers, screws or slide gates, weigh chambers, and mixer surfaces that can trap pellets and create cross-contamination. Compare how long it takes to empty, wipe down, and inspect each machine between runs, and define your acceptable retained-material limit before choosing a multi-hopper frame.

On records: a display showing a percentage is not a batch record. Ask which values are measured, which are calculated, and which an operator typed in. If you need material-use totals or alarm history for traceability, say so before the controls are specified, because retrofitting them is a controls project.

How we scope these

We supply volumetric dosers and gravimetric blenders across our Zhongshan factory and manufacturing partners in the mixing and dosing line. In a quotation we state the measurement principle, the feeder or gate arrangement, the hoppers and loaders included, the calibration procedure, and the material condition the rating assumes. The gravimetric blender series and the production-cell gravimetric blender cover most multi-component recipes; the multi-hopper color dosing and conveying station is the option when several color streams and conveying are one package.

What we need from you is the full recipe with weight percentages and tolerances, every material by name and grade with particle form and bulk density, minimum and peak consumption, the number of recipes and changeover frequency, mounting location, refill method, electrical supply, and what the records have to show. Send material samples with the consumption profile to KYSHIN and we can put a machine-level RFQ together that names the measurement method rather than leaving it to the model number.

Send us your material and process details

We will review the application before recommending a machine configuration.

Request a quote
Request a quoteWhatsApp