RFQ checklistPublished:

Resin Drying System RFQ Checklist for Injection Molding Plants

Four numbers size a resin drying system: kg/h, drying time, bulk density and usable hopper volume. What else belongs in the RFQ, and where cheap quotes hide.

Resin Drying System RFQ Checklist for Injection Molding Plants guide cover

Two suppliers answer the same drying RFQ. One quotes a 200 L hopper, the other a 500 L. Both can defend their number, and the gap usually is not sharp practice: the RFQ never said how long the resin has to sit at temperature, so each supplier assumed something different. That one missing line matters more than every other specification in the package.

An RFQ does not have to look complete. It has to make the supplier show the arithmetic behind the vessel.

Four numbers decide the dryer

Hourly consumption per grade in kg/h. The drying time the resin supplier states for that grade. Bulk density in kg/L. The usable volume between the low and high level of the hopper you are being offered.

Multiply the first two, divide by the third, and you have the liters of working inventory the process actually needs. Compare that with the fourth and the sizing argument is settled before the price comparison starts.

A supplier who asks for all four is doing engineering. One who asks only how many presses you run is selling vessel volume, and vessel volume is the cheapest line to add to a quotation.

What the package has to contain

Five inputs carry most of the weight, and each one changes the equipment:

  1. Each grade by producer and full name. "PA6" covers unfilled, 30 % glass, impact-modified and flame-retardant compounds whose approved drying windows can sit 15–20 °C apart, in either direction. The compounder's sheet for that compound is the only document that says which; a glass-filled grade does not automatically want a hotter dryer, and it must not be pushed past its stated limit.
  2. Target residual moisture and the test method behind it. Karl Fischer and a loss-on-drying analyzer return different numbers on the same pellets, so a 0.05 % limit quoted by Karl Fischer and an incoming check on a halogen analyzer will argue about instruments instead of resin.
  3. Average and peak consumption in kg/h, with the arithmetic visible. Shot weight times shots per hour, plus runners, rejects and purge. A supplier cannot size shared air from a nameplate.
  4. The drying time, and whether it assumes dry air. A four-hour recommendation written for −20 °C dew point air is not a four-hour recommendation for ambient air.
  5. The route from hopper to feed throat. Distance, lift, bend count, whether the conveying air is dried, and how long pellets sit in a receiver before the press pulls them.

What gets left out of most RFQs is not an input. It is a behavior: what the system does when the press stops for ninety minutes, and whether the material stays under dry air at temperature or cools down wet inside the hopper.

A four-press cell on PA6, worked through

A cell of four presses, each running a 250 g shot on a 28-second cycle. That is roughly 129 shots an hour per press, so about 32 kg/h, and 128 kg/h for the cell.

PA6 wants four hours at the hopper for a standard unfilled grade. 128 × 4 = 512 kg of resin that has to be at temperature, under dry air, at any moment. Pellets bulk around 0.60–0.72 kg/L, so 512 kg is 710–850 L of working inventory; take 710 L from the dense end of that range and it is still 710 L you cannot avoid.

Split four ways, that is 178–213 L per press. A machine-side three-in-one dryer at 200 L sounds right and may not be: the nameplate includes the cone and the space above the high-level mark, and the usable band between low and high level on a small unit is often 150–165 L. The ask is not "200 L". It is a working band that covers 180 L at the fill levels you intend to run, and the nameplate will not tell you that.

The alternative is one central drying system with an 800 L hopper feeding all four presses. That solves the volume and creates a second problem: the dried resin now travels, and every meter of that path is a chance to pick moisture back up. Central is worth it when you already have a dry room, a vacuum network and someone who owns them.

Dew point is where cheap drying quotes hide

Drying is a water-content problem before it is a temperature problem. Air at 20 °C and 60 % relative humidity carries about 10 g of water per cubic meter; −20 °C dew point air carries about 1 g, and −40 °C about 0.1 g.

A dryer that heats ambient air to 80 °C delivers hot air that is still carrying the plant's absolute moisture: about 10 g/m³ at 20 °C and 60 % relative humidity, which is a dew point near 12 °C. At 80 °C that air is at only about 3 % relative humidity, so the pellets feel dry, but the water it can still absorb is roughly ten times what −20 °C air holds, and the bed flattens out above the target long before the hours run out. Hours are not the variable. Absolute moisture is. For most PA6 work, process air at −20 °C dew point is the usual working figure; −30 to −40 °C is common where the target is 0.05 % or the plant sits in a humid climate. Desiccant wheel and twin-tower designs both get there; what separates them in practice is regeneration heat, maintenance intervals, and whether dew point holds at low load.

Ask for dew point at the hopper inlet, at full load and half load, and where the sensor sits. A reading taken inside the cabinet is not the air the pellets see.

Three things in the offer deserve the same scrutiny, because they are where a cheap system is cheap: heater capacity against the airflow actually delivered, air distribution through the bed (a 500 mm bed with a single diffuser dries unevenly, and the top layer is the layer that reaches the press last), and whether the conveying air is dried. Vacuum conveying on ambient air is a moisture injection system wearing a material-handling label.

What else belongs in the package

The four numbers size the machine. Five more lines decide whether the quote can be executed, and they are the ones buyers most often leave out:

  • Incoming moisture, not just target. Sealed virgin, open bags, stored regrind and the worst seasonal condition are different loads, and the load sets residence time as much as the target does. If nobody has measured it, say so and ask what load the sizing assumes.
  • Simultaneous demand. For a central option, which presses can run at the same time is a different question from how many presses you own. Nameplate totals do not add up into shared air.
  • Space and structure. Floor area, ceiling height, platform position, mounting load and cleanout access decide whether the central option physically exists.
  • Utilities. Voltage, phase and frequency at the point of connection, connected load, compressed air, cooling water and drainage. A dryer with the right dew point and the wrong supply is still the wrong dryer.
  • Compliance evidence and wear parts. Which document proves the quoted configuration meets your destination rules, and the price and lead time for desiccant media, filters and heaters. An eight-week rotor is a different support story from a two-week filter.

Acceptance: test the resin, not the display

A low dew point reading on the controller proves the dryer works. It does not prove the pellets reached target. The acceptance test should pull a sample at the machine inlet, not the hopper outlet, from the material the press is about to run, and measure it by the method written into the resin specification. Three samples across one shift is a reasonable minimum, in sealed dry containers, because a warm dried pellet in an open cup picks up moisture on the way to the balance. And no setpoint fixes a bridged cone or a conveying line left full overnight.

Before that, agree who supplies the trial resin, who runs the test, and what the ambient was that day. Performance quoted at 20 °C and 50 % relative humidity, measured in a plant at 32 °C and 85 %, is a different machine.

What we need to size this properly

Send the grade and its data sheet, the shot weight and cycle time for each press, the number of machines, regrind percentage, mounting height at each press, and the summer humidity if anyone has measured it. With those we return a hopper volume, a usable band at your fill levels, dryer type, dew point and airflow, and the conveying arrangement if the drying goes central.

KYSHIN supplies hopper dryers, resin dehumidifiers and machine-side or central drying systems, assembling at our Zhongshan factory and through manufacturing partners for part of the range — we will tell you which line comes which way when it matters to your schedule. If your arithmetic does not support the system you asked for, we would rather say so before the order than during commissioning.

Send us your material and process details

We will review the application before recommending a machine configuration.

Request a quote
Request a quoteWhatsApp