title: "Dosing Regrind with Variable Particle Size: What to Test | KYSHIN Machinery"
url: "https://kyshinmachinery.com/guides/regrind-dosing-particle-size"
language: "en"
description: "A 28% shortfall can hide in a volumetric feeder when regrind bulk density drops, so calibrate and verify batch weight on actual regrind."
---

[Home](https://kyshinmachinery.com/) / [Guides](https://kyshinmachinery.com/guides) / Dosing Regrind with Variable Particle Size: What to Test

Selection Guides Published: November 5, 2026

# Dosing Regrind with Variable Particle Size: What to Test

Regrind particle size varies. Learn what to test in gravimetric blending: bulk density, calibration, refill, and record keeping with practical checks.

![KYSHIN editorial cover: Dosing Regrind with Variable Particle Size: What to Test; conceptual illustration](https://kyshinmachinery.com/images/guides/q4-2026/regrind-dosing-particle-size.webp)

A 30 % regrind recipe that holds ±0.5 % batch weight on Monday can wander to ±2 % on Thursday without anyone touching a setpoint. Nothing failed. The granulator screen was swapped, or the knives wore, or a different lot of the same resin went in, and the regrind's bulk density moved. If your feeder doses by volume, that density change goes straight into the part.

So the test is not "does the blender hold a recipe." It is "how far does batch weight move when the regrind moves, and does the system correct for it." That question has a measurable answer, and it takes about a shift to get.

## Bulk density is the number that shifts under you

Volumetric feeders deliver a volume. Change the bulk density and the delivered mass changes with the auger untouched. Virgin pellet bulk density sits in a fairly tight band for a given grade — solid PP homopolymer has a material density of 0.90–0.91 g/cm³ and a pellet bulk density commonly around 0.52–0.58 kg/L, while ABS has a solid density of 1.04–1.06 g/cm³ and a pellet bulk density around 0.60–0.66 kg/L. Regrind from the same material is looser and more variable, often 0.35–0.50 kg/L depending on screen size, flake geometry, and fines content, because irregular particles pack with more air between them.

That gap is the whole problem. A volumetric auger set to deliver 3 kg/h of virgin pellets at 0.60 kg/L is moving 5.0 L/h of volume. Feed it regrind at 0.43 kg/L and the same 5.0 L/h now carries only 2.15 kg/h — a 28 % shortfall in the regrind stream, with every dial reading exactly what it read before.

A gravimetric blender weighs what it delivers, so it can chase that change within its calibration range. But the feeder still has to present material consistently for the weight signal to mean anything. That is why the first test is a density check, not a controller setting: pull a measured volume of each component as received, weigh it, and write the number down. Two lots minimum if your regrind supply varies.

## Calibrate on the regrind, not on pellets

Most calibration procedures were written around virgin pellets, and a clean pellet sample will pass a calibration that the real regrind fails. Run the check with the actual particle size distribution you intend to run in production.

The principle is the same on any feeder: collect material over a known interval, weigh it, compare to target, adjust. On a volumetric unit that means catching the auger output in a bucket for, say, 60 seconds and weighing it. On a gravimetric unit the controller does the weighing, and the check becomes whether the delivered weight matches the setpoint over a full batch cycle.

Fines are the part that surprises people. A regrind load with a heavy fines fraction can fluidize in the feeder throat, so it flows faster than the auger speed implies, or it compacts and bridges, so it flows slower. Either way the flow behavior changes when the screen changes, because a different screen makes a different distribution. Repeat the calibration after any screen or knife change, not just after a resin change.

## A worked example: what 30 % regrind does to a batch

Take a 2 kg batch, 70 % virgin PP and 30 % regrind, so 1.4 kg virgin and 0.6 kg regrind. Suppose the volumetric feeder was calibrated when a clean, coarse regrind measured 0.50 kg/L, and the auger was set to move the volume that delivers 0.6 kg — that is 1.2 L per batch.

Now a finer screen goes in and the regrind bulk density drops to 0.40 kg/L. Same 1.2 L, but now it carries 0.48 kg. The batch comes out at 1.88 kg, and the regrind fraction has fallen from 30 % to 25.5 % (0.48 ÷ 1.88). The virgin mass per batch is unchanged; the color and the mechanical properties are not, because the regrind was carrying both.

On a gravimetric blender the same shift shows up as the controller adding volume to hit 0.6 kg by weight, and the batch stays at 2 kg. That is the difference the test is measuring: not accuracy in the abstract, but whether a density change lands in the part or gets absorbed.

Scale that to a press running 40 kg/h of total throughput. If the press pulls 40 kg/h from a volumetric system whose regrind stream has dropped from 30 % to 25.5 % of the total mass, the press consumes 10.21 kg/h of regrind instead of the intended 12.0 kg/h — a shortfall of 1.79 kg/h replaced by extra virgin resin as the throat draws more batches per hour to keep the screw full (or if the blender fires a fixed 20 batches/h, the regrind feed drops by 2.4 kg/h from 12.0 to 9.6 kg/h). Over a 24-hour run at 40 kg/h press demand, that is 43 kg of regrind left in the bin and replaced by virgin resin that the cost sheet never budgeted for.

## Refill and low-level behavior is where full-hopper tests lie

A blender that holds weight beautifully on a full hopper can behave differently as the bin empties. Fluffy regrind with fines does not flow at the same rate as pellets, and near the low-level point the feeder may surge, starve, or see a weight signal that lags the actual delivery.

Run the refill test at the lowest level you expect in production, not at a comfortable full bin. Watch the refill interval, watch for surging, and note any manual intervention. What you are documenting is whether the system holds the recipe from full to empty. If it does not, the fix is usually feeder configuration or a material-handling change upstream — a different receiver, a [vacuum loader](https://kyshinmachinery.com/products/feeding-conveying/vacuum-autoloader-with-storage-bin) sized for the regrind's flow, or a storage bin that lets the material settle before it reaches the auger — rather than a number you guess at in the controller.

## Keep a record that ties particle size to batch weight

For each run, log the regrind source, the granulator screen if you know it, the measured bulk density, and the actual batch weight per component. Sieve data, if you have it, attaches to the same line. A shift log that links a particle size change to a weight deviation tells you more than any single pass/fail result, because over several runs you can see whether one regrind lot consistently misses target.

That record also does something practical when you call a supplier: it separates a material problem from a mechanical one. A single out-of-spec batch is not proof of a feeder fault. It might be a density shift or a bridging event, and the log is what tells you which.

## Where a gravimetric blender earns its place, and where it does not

If your regrind varies widely and you are dosing volumetrically today, weight-based blending removes the density assumption from the recipe. Our [gravimetric blender series](https://kyshinmachinery.com/products/mixing-dosing/gravimetric-blender-series) prepares multi-material batches by weight and configures to the number of components in the recipe.

It is not a guarantee of accuracy, and we would not sell it as one. A gravimetric blender corrects for density within its calibration range; it cannot fix regrind that bridges in the hopper or fines that fluidize past the feeder. Those are material-handling problems, and they show up as weight-signal noise no controller setting will smooth out. We supply dosing and recycling equipment from our factory in Zhongshan and through manufacturing partners for some items, and we size the blender around your actual regrind and the tests above, because a unit specified on virgin-pellet assumptions is the same mistake in a more expensive box.

If the whole path from granulator to feed throat is in scope, our [in-house recycling solutions](https://kyshinmachinery.com/products/granulating-recycling) cover the granulator side, and the blender sits at the end of it. Send your regrind sample details and recipe percentages and we will work through a configuration with you.

Request a quote

## Send us your material and process details

We will review the application before recommending a machine configuration.

[Request a quote](https://kyshinmachinery.com/contact)

<https://kyshinmachinery.com/guides/regrind-dosing-particle-size>