Maintenance Published: October 23, 2026

# Why a Gravimetric Blender Misses the Target Recipe

A practical diagnostic guide to why a gravimetric blender misses its target recipe: weigh-cycle checks, refill disturbance, component range and records.

![KYSHIN editorial cover: Why a Gravimetric Blender Misses the Target Recipe; conceptual illustration](https://kyshinmachinery.com/images/guides/q4-2026/gravimetric-blender-recipe-accuracy.webp)

A 3 % masterbatch recipe that runs 2.6 % for an hour and then corrects to 3.4 % is not a blender with a bad setpoint. It is a blender whose reference moved. Gravimetric dosing works by weighing what it dispenses and adjusting the auger to hit a target by mass, so when the batch comes out off-recipe the error is almost always in the weighing, the feeding, or the reference the controller is measuring against — not in the number someone typed into the recipe screen. "Gravimetric" names the principle. It does not promise the result.

## First decide what kind of miss you have

The percentage on the display is not the batch. Before anything is adjusted, get the actual numbers: which component drifted, in which direction, and when it started. A masterbatch that reads low at startup and settles by mid-shift points somewhere different from one that drifts after every refill.

Watch whether the error stays on one component or migrates. A single wandering feeder is a feeder problem. Every component drifting the same direction at once is usually a reference problem — the base resin weight the controller divides by, or the recipe basis itself.

One distinction gets skipped constantly: percentage by weight of the base resin versus percentage of the total blend. Adding 3 kg of masterbatch to 100 kg of base resin is 3.00 % against base resin, but 2.91 % of the 103 kg total blend (and the gap widens when 20–30 % regrind is in the mix). A controller configured for one basis will look wrong against a QC sheet written for the other while dosing perfectly.

## The weigh cycle is the reference, and it can lie

Every gravimetric controller builds its correction on a weigh reading. The minor component is dispensed into a weigh chamber, the load cell reads it, and the controller compares that mass to target. If the reading is disturbed, the correction is built on bad data and the next cycle inherits the error.

Three things disturb it in practice. Vibration from a running granulator or a vacuum loader on the same frame. Material still falling into the chamber when the reading is taken. And a chamber being loaded during the weighing step because the gate sequence and the feeder are out of phase.

The smallest admitted weight per cycle is where this bites hardest. Suppose a 500 kg/h blend runs a 2 kg weigh batch, so 250 batches an hour. A 1 % additive is 20 g per batch. A load cell with 1 g resolution reads that 20 g to ±5 %, and if the feeder's minimum reliable dose is 15 g, the controller is chasing a target right at the bottom of its controllable envelope. Shrinking the batch makes that worse (a 1 kg batch drops the dose to 10 g, below the feeder floor and at ±10 % load-cell resolution). The fix is either a larger weigh batch where cycle rate allows — say a 5 kg batch so the 1 % dose becomes 50 g — or a dedicated micro-feeder with a smaller auger and higher-resolution weighing, not a new setpoint.

Calibration procedures also differ between controller families, so always follow the manual for the actual model installed, and leave any work inside the electrical enclosure to qualified personnel under the plant's lockout and isolation procedure.

## Refill and flow move a recipe that was stable

A refill is a disturbance. The loader drops a slug of material into the hopper, the frame takes a knock, and for a few seconds the weigh reading is not trustworthy. If the refill lands mid-weigh, that cycle is corrupt.

Look for a pattern that follows loader activity rather than production time. If the drift lines up with refill pulses, the answer is usually sequencing — pausing the loader during the weigh step, or coordinating low-level detection with the dosing cycle — rather than recalibrating anything.

Empty hoppers cause a second kind of error. As a hopper runs down, head pressure and flow change, and a feeder calibrated on a full hopper delivers a different mass near empty. Bridging regrind, sticky additives, dust, and irregular flake all interfere with repeatable feed into the weigh step, and the symptom alone will not tell you which one you have. Poor venting restricts discharge and looks identical to a bridging problem until you open the hopper.

Material that is not what the blender was configured for is the other half. Particle size, shape, and bulk density change delivered mass per auger revolution. A regrind lot that runs 15 % lighter than the virgin it replaced feeds light at the same auger setting, and the controller corrects — until it runs out of correction range.

## Some misses start upstream and downstream of the blender

A blend can leave the mixer correct and arrive at the machine wrong. When component particles differ in size and density, conveying separates them: the heavy pellets settle, the light additive rides the air. A recipe verified at the blender outlet is not verified at the hopper.

Upstream, check that virgin, regrind, and masterbatch lines are connected and labeled to match the recipe, that a shared loader sequence has not swapped source identities, and for hygroscopic resin, whether drying happens before or after dosing — because moisture changes mass, and a gravimetric recipe that assumes dry resin will read high on wet material. Our [central material conveying system](https://kyshinmachinery.com/products/feeding-conveying/central-material-conveying-system) and the loaders that feed a blender are part of that path, and separation at transfer is a real limit of any gravimetric system, not a defect in the blender.

## When the component cannot be held at the rate

Here is the honest limitation. A gravimetric blender is accurate within the range its feeders can dose and its load cells can resolve. Ask it to hold 0.2 % of a 400 kg/h blend — 0.8 kg/h — and you are below what a standard auger feeder delivers repeatably, no matter how good the controller. The error is not a tuning problem; the ratio is outside the hardware.

The same applies at the top end. A feeder sized for 2–20 kg/h will not hold a 30 kg/h component, and forcing it means running wide open with no correction authority left.

We supply and configure the [Gravimetric Blender Series](https://kyshinmachinery.com/products/mixing-dosing/gravimetric-blender-series) across our factory in Zhongshan and our manufacturing partners from the material list, the recipe percentages, total hourly demand, and the minimum component ratio and bulk densities — because those four numbers decide the feeder arrangement before any setting does. When the smallest component falls outside a standard feeder's range, the answer is often a different feeder layout or a dedicated small doser, and we will say so rather than promise an accuracy figure the hardware cannot meet.

## What actually settles the question

Bring the evidence, not the conclusion. Every material name and grade, its particle form and bulk density, the target percentage and its acceptable range, total minimum and peak consumption, the number of recipes, refill method, upstream drying, and downstream conveying. Add the defect map — which cavity or line, when in the shift, how often — the calibration history, and any recent change to material, hose routing, or maintenance.

If the batch record shows the blender weighing correctly and the recipe basis wrong, no mechanical adjustment fixes it; the recipe definition does. If the record shows the reference disturbed by refill or vibration, the fix is sequencing and isolation. And if the numbers show the component ratio sits outside the feeder's controllable range at your total rate, the honest answer is a different measurement approach, not a smaller tolerance. Knowing which of those three you have is most of the job.